Fluke 1621 user manual




















Page 4 Users Manual Page 6 Users Manual Page 8 Users Manual Page Safety Regulations Users Manual Safety Regulations This measuring device is only to be installed and operated by qualified personnel in compliance with the safety precautions and regulations that follow.

Additionally, the use of this equipment requires compliance with all legal and safety regulations pertaining to each specific application. Similar regulations apply to the use of accessories. Page Symbols Conforms to relevant European Union directives Do not dispose of this product as unsorted municipal waste. Contact Fluke or a qualified recycler for disposal. The enclosure is designed for V CATII pollution degree 2 to cover unintended connection to hazardous fault voltages at the earthing system.

Features and Functions The software version displays. Page 20 Users Manual Aux. Three-Pole Measurement Setup Set the rotary switch to OFF. See Figure 5. Connect the test leads to each end of the conductor under test. Table 4. Troubleshooting Step Description Auxiliary electrode resistance R too high If the auxiliary electrode resistance is too high exceeds ke , it is not possible to drive the current necessary for reliable measurements.

Page Specifications Earth Ground Tester Specifications Specifications Note Fluke reserves the right to modify specifications without notice for the purpose of product improvement. Measuring functions: 3-pole earth ground resistance, 2 pole AC resistance of a conductor Interference voltage Intrinsic error: Refers to the reference temperature range and is Print page 1 Print document 26 pages. The Fluke is an easy-to-use earth ground tester. The first line of defense in detecting reliable ground connections, the unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance.

Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth tester, for most work environments. With a simple user interface and intuitive functionality, the Fluke is a handy tool for electrical contractors, utility test engineers, and earth ground specialists.

Note: If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage. Note: The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use. Welcome to ManualMachine.

We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions.



0コメント

  • 1000 / 1000